Medical device tray sealer
1518S Single Shuttle
A compact tray sealer with a 15″ × 18″ sealing platen and manual single shuttle loading, configurable with automatic shuttle, pressure control, tool recognition and safety light curtain options.
- Heat sealing area
- 15″ × 18″
- 38.1 × 45.7 cm
- Sealing force
- Up to 5,000 lb
- Adjustable
- Floor space
- 51″ × 30″
- 130 × 76 cm
- Loading
- Single shuttle
- Manual standard, automatic optional
Overview
Compact by design, configurable for your process
The 1518S is the most compact sealer in the Atlas Vac range. It is supplied ready for operation on connection to air and electric power, and can be specified from manual loading through to fully automatic shuttle and pressure control.
-
Compact, mobile footprint
A 51″ × 30″ footprint on height-adjustable stainless casters, built on a rigid welded 3/16″ steel tubular frame with a rear-mounted NEMA 12 controls enclosure.
-
Stable, repeatable sealing force
A 6″ dual-stage cylinder, made in the USA, applies adjustable force of up to 5,000 lb onto a precision stationary tool base, so the tooling remains still and aligned during each seal.
-
Quick tooling changeover
A lift-off aluminum tooling shuttle with stainless locator pins positions each nest positively, running on 1″ stainless shafts with linear ball bearings.
Specification
Standard specification
Values describe the standard 1518S configuration. Electrical supply is specified at order; optional equipment may change the arrangement shown in drawings.
Sealing
1518S| Heat sealing area | 15 in. × 18 in. (38.1 × 45.7 cm) |
|---|---|
| Sealing force | Adjustable up to 5,000 lb |
| Press | Pneumatic, 6″ diameter dual-stage cylinder |
| Heat plate | 1″ flat plate with internal heaters, 3,000 W, 240 V or 480 V |
| Seal platen | Precision-machined aluminum, DuPont Teflon Silverstone coating |
Machine
1518S| Loading | Manual single shuttle, clear-anodized aluminum |
|---|---|
| Tooling shuttle | Quick-change lift-off shuttle with stainless steel locator pins for positive location of the tooling nest |
| Floor space | 51″ × 30″ (130 × 76 cm) |
| Frame | Welded 3/16″ steel tube, white powder coat |
| Mobility | Non-mar stainless casters with height adjustment |
| Controls enclosure | NEMA 12, rear mounted |
| Weight | To be confirmed |
| Tool-height opening | To be confirmed |
Utilities
1518S| Electrical | 3 kW; 220, 220/240, 380 or 480 V; single or three phase, as configured |
|---|---|
| Power cable | 9 ft, ready for a customer-supplied plug |
| Compressed air | 0.35 CFM at 80 PSI, measured at 4 cycles per minute |
| Air supply | 100 PSI on a ¾″ minimum line |
| Filtration | 5 micron inlet filter (¾″ NPT); 20 micron exhaust filter or room discharge connection |
Safety
1518S| Cycle start | Two-hand Banner Opti-Touch safety-rated sensors, per OSHA 1910.212 and 1910.144 |
|---|---|
| Emergency stops | Two, with stationary yellow/red safety shields; meet CE, UL, CSA, OSHA and ISO 13850 |
| Guarding | Stainless steel and Lexan shuttle guards on bottom and sides, meeting OSHA 1910 Subpart O, 1910.145, EN 415-1 and -3 |
| Touch protection | Components compliant with IEC 60204-1, and with CE, CSA and UL as applicable |
| Overtemperature | Redundant automatic heater cutoff, CE-approved controller, 300°F standard |
Heater rating covers the platen heaters only, not the total connected electrical load. Air consumption is rated at a test condition, not at a production rate.
To be confirmed Awaiting confirmation from Atlas Vac
Standard controls
Process control and monitoring as standard
Every 1518S is controlled by an industrial PLC, with password-protected recipes, alarm limits and calibration access built in.
Records, data export and integration-
Control platform
- Mitsubishi FX5u PLC
- Beijer 10″ color touchscreen at eye level
- English or metric readouts
-
Recipes and access
- Multiple stored recipes
- ID and password sign-in with supervisor, engineer and calibration levels
- Password-protected recipes and calibration screens
- Individual operator sign-in (optional)
-
Monitoring and alarms
- On-screen time and temperature control with alarm limits
- Temperature and air pressure sensor fail-safe alarms
- Short-cycle alarm requiring supervisor acknowledgement
- Alarm history and multi-color LED alarm light
-
Calibration
- Four dual-lead thermocouples with individual calibration connectors
- Pressure calibration port and 24 VDC timer connector
- On-screen calibration of temperature and pressure circuits
-
Data and traceability
- Logging of sign-on, changes and UDI process data on every cycle
- Manual offload only; records cannot be edited
- Two powered USB ports for a barcode scanner (not included); manual entry on screen also permitted
- Recipe matching to barcoded tooling and device paperwork
-
Pressure and counters
- Precision manual pressure regulator with liquid-filled gauge
- Odometer and resettable cycle counter
Options
Configure your 1518S
Start from the standard manual configuration and add the equipment your process requires. Several options build on automatic shuttle and automatic pressure control, as shown below.
How each option worksStandard
Supplied with every 1518S
- Manual single shuttle
- Manual pressure regulator with gauge
- Two-hand safety start sensors
- FX5u PLC and 10″ touchscreen
- Redundant overtemperature cutoff
Ready for operation on connection to air and electric power.
Full specification ↑Foundation options
Enable the advanced options
Advanced options
Each lists the options it requires
Further options
- Stainless steel framework and controls cabinet
- 4.9 gallon ASME air reservoir with relief valve
- Calibration, IQ and OQ services
- Translated PLC screens and manuals
- CE rating certification
- UL listing on controls cabinet
Drawings and documents
Configuration drawings
Dimensioned drawings for two common 1518S configurations. Each applies to the configuration shown; Atlas Vac confirms the drawing for your ordered configuration.
-
Configuration-specific reference1518S Auto Shuttle
Drawing 61-26-87-1-6-1 · Single shuttle sealer with the Auto Shuttle option. Download PDF -
Configuration-specific reference1518S Light Curtain CE
Drawing 692021-SK-1-3 · Single shuttle sealer with the Class 3 light curtain option. Download PDF
Supplied with every 1518S
- Owner’s manual (one copy)
- Schematics and Atlas Vac programs on USB flash drive
- Air inlet filter and pressure gauge
- Ready for operation on connection to air and electric power
Project enquiries
Discuss your 1518S application
Our engineers will review your package and production requirements and recommend the 1518S configuration and tooling that suit your process.
Useful if you have it
Tray drawing or sample tray · Lidding material · Options of interest
- Address
- Atlas Vac Machine, LLC
9150 Reading Rd
Cincinnati, OH 45215, USA - Phone and email
- (513) 407-3513
sales@atlasvac.com - Hours
- Mon–Fri 08:00 am – 05:30 pm
Saturday by appointment
Sunday closed