Medical device tray sealer
1830S Single Shuttle
The largest pneumatic platen in the Atlas Vac range: 18″ × 30″, with an 8″ dual-stage cylinder, tool-height opening up to 4.5″ and a shuttle that accepts standard 15:18 or 18:30 tooling.
- Heat sealing area
- 18″ × 30″
- 45.7 × 76.2 cm
- Sealing force
- Over 10,000 lb
- Adjustable
- Tool-height opening
- Up to 4.5″
- Others on request
- Loading
- Single shuttle
- Manual standard, automatic optional
Overview
Large-format sealing on a pneumatic platform
The 1830S suits larger trays and multi-cavity tooling. It is supplied ready for operation on connection to air and electric power, with an air reservoir and CE safety-rated isolation valve included.
-
8″ cylinder on a precision surface plate
Force adjustable to over 10,000 lb from an 8″ dual-stage cylinder, made in the USA, onto a Blanchard-ground, nickel-plated steel surface plate held flat to .001″–.003″.
-
Accepts 15:18 and 18:30 tooling
The lift-off shuttle has mounting holes for two standard Atlas Vac 15:18 tools or one standard 18:30 tool, with stainless locator pins. Atlas Vac confirms fit for each package.
-
Operator staging shelf
A stainless steel shelf at operator eye level stages packaging materials, with under-shelf LED lighting over the loading area.
Specification
Standard specification
Values describe the standard 1830S pneumatic configuration. Electrical supply is specified at order; optional equipment may change the arrangement shown in drawings.
Sealing
1830S| Heat sealing area | 18″ × 30″ (45.7 × 76.2 cm) |
|---|---|
| Tool-height opening | Up to 4.5″; others on request |
| Sealing force | Adjustable to over 10,000 lb |
| Press | Pneumatic, 8″ diameter dual-stage cylinder |
| Heat plate | Flat 1″ plate with internal heaters, 6,000 W, 240 V or 480 V |
| Seal platen | Precision-machined aluminum, DuPont Teflon Silverstone coating included |
| Surface plate | Blanchard-ground, nickel-plated steel, flat to .001″–.003″ |
Machine
1830S| Loading | Manual single aluminum shuttle on 1″ stainless shafts |
|---|---|
| Tooling shuttle | Quick-change lift-off shuttle with stainless steel locator pins for tooling plates |
| Floor space | 45″ W × 55″ L (114 × 140 cm) |
| Frame | Welded 3/16″ steel tube, white powder coat; NEMA 12 enclosures under the frame |
| Mobility | Non-mar casters with height adjustment and brakes |
| Staging | Stainless eye-level shelf with under-shelf LED lighting |
| Weight | To be confirmed |
Utilities
1830S| Electrical | 208, 220/240, 380 or 480 V; single or three phase; others on request |
|---|---|
| Compressed air | 11–13 CFM at 80 PSI, measured at 4 cycles per minute |
| Air supply | 100 PSI on a ¾″ minimum line; 5 micron inlet filter |
| Air reservoir | 4.7 gallon ASME or 25 L CE, with certified relief valve |
| Exhaust | Single port with 20 micron filter or room discharge connection; sound levels comply with OSHA 1910.95 |
| Power cable | 9 ft, ready for a customer-supplied plug |
Safety
1830S| Cycle start | Two-hand Banner Opti-Touch safety-rated sensors, per OSHA 1910.212 and 1910.144 |
|---|---|
| Isolation | Pneumatic CE safety-rated isolation lockout valve |
| Guarding | Stainless operator guards on Auto Shuttle models, meeting OSHA 1910 Subpart O, 1910.145, EN 415-1 and -3, and ISO 12100:2010 |
| Emergency stops | Stationary yellow/red safety shields; meet CE, UL, CSA, OSHA and ISO 13850 |
| Controls design | NFPA 79 compliant |
| Touch protection | Components compliant with IEC 60204-1, and with CE, CSA and UL as applicable |
| Overtemperature | Redundant automatic heater cutoff, Factory Mutual approved controller, 300°F standard |
Floor space is the machine footprint; additional room is required for installation and service access. Heater rating covers the platen heaters only, not the total connected electrical load. Air consumption is rated at a test condition, not at a production rate.
To be confirmed Awaiting confirmation
Standard controls
Recipe control for large-format tooling
Recipes, alarm limits and calibration are managed from a 10″ touchscreen at eye level, with sign-in levels for operators, supervisors and calibration staff.
Records, data export and integration-
Control platform
- Mitsubishi FX5u PLC
- Beijer 10″ color touchscreen at eye level, storing multiple recipes
- English (default) or metric readouts
-
Recipes and access
- On-screen time and temperature control with alarm limits
- Supervisor, engineer and calibration sign-in levels
- Individual operator sign-in (optional)
-
Pressure
- Precision manual regulator with liquid-filled gauge
- On-screen digital pressure readout
- Pressure calibration port with on-screen calibration
-
Calibration
- Four dual-lead thermocouples with individual calibration ports
- On-screen, password-protected thermocouple calibration
- 24 VDC timer calibration connector
-
Data and traceability
- Logging of sign-on, recipe changes, UDI and process data on every cycle
- USB data offload; records cannot be edited
- Two powered USB ports for a barcode scanner (not included); manual entry on screen also permitted
- Recipe matching to barcoded tooling and device paperwork
-
Monitoring and alarms
- Temperature and air pressure fail-safe alarms
- Alarm detail history on screen and in memory
- Multi-color LED signal light
- Odometer and resettable cycle counter
Options
Configure your 1830S
The 1830S is offered with either a vertical or a horizontal light curtain arrangement, each documented in its own drawing. Automation and verification options build on automatic shuttle and pressure control.
How each option worksStandard
Supplied with every 1830S
- Manual single shuttle
- Manual regulator with digital readout
- Air reservoir and isolation valve
- Staging shelf with LED lighting
- FX5u PLC and 10″ touchscreen
Ready for operation on connection to air and electric power.
Foundation options
Enable the advanced options
Advanced options
Each lists the options it requires
Further options
- Stainless steel framework and controls cabinet
- Horizontal light curtain arrangement (see drawing 2252022-SK)
Drawings and documents
Configuration drawings
Three dimensioned drawings cover the Auto Shuttle and both light curtain arrangements. Each applies to the configuration shown; Atlas Vac confirms the drawing for your ordered configuration.
-
Configuration-specific reference1830S Auto Shuttle
Drawing 1042013-SK Download PDF -
Configuration-specific reference1830S Vertical Light Curtain
Drawing 592018-SK Download PDF -
Configuration-specific reference1830S Horizontal Light Curtain CE
Drawing 2252022-SK Download PDF
Supplied with every 1830S
- Owner’s manual with operation and maintenance information
- Recommended spares list
- Schematics and the Atlas Vac calibration document
- Atlas Vac PLC programs on USB flash drive
Tooling nests are quoted separately. Factory acceptance testing and additional documents are quoted by scope.
ToolingProject enquiries
Discuss your 1830S application
Our engineers will review your package and production requirements and recommend the 1830S configuration and tooling that suit your process.
Useful if you have it
Tray drawing or sample tray · Lidding material · Options of interest
- Address
- Atlas Vac Machine, LLC
9150 Reading Rd
Cincinnati, OH 45215, USA - Phone and email
- (513) 407-3513
sales@atlasvac.com - Hours
- Mon–Fri 08:00 am – 05:30 pm
Saturday by appointment
Sunday closed